I-SA-6600

I-Analyzer ye-Blood Rheology Ezenzakalelayo Ngokugcwele

1. Yakhelwe iLabhorethri Yezinga Eliphakathi.
2. Indlela ephindwe kabili: Indlela yepuleti le-Rotational Cone, indlela ye-Capillary.
3. Umaka ojwayelekile ongeyona iNewtonian uwina isitifiketi sikazwelonke saseShayina.
4. Izilawuli Zokuqala Ezingezona EzaseNewtonia, Izinto Ezisetshenziswayo kanye nokusetshenziswa kwenza ikhambi eliphelele.


Imininingwane Yomkhiqizo

Isingeniso Sokuhlaziya

I-SA-6600 ezenzakalelayo i-rheology analyzer isebenzisa imodi yokulinganisa uhlobo lwekhoni/ipuleti. Umkhiqizo ubeka ukucindezeleka okulawulwayo kuketshezi okufanele kulinganiswe nge-motor ye-torque ephansi ye-inertial. I-drive shaft igcinwa endaweni ephakathi nge-magnetic levitation bearing ephansi yokumelana, edlulisela ukucindezeleka okubekwe kuketshezi okufanele kulinganiswe futhi ikhanda lalo lokulinganisa liwuhlobo lwekhoni-ipuleti. Ukuhlolwa konke kulawulwa ngokuzenzakalelayo yikhompyutha. Izinga lokugunda lingabekwa ngokungahleliwe ebangeni le-(1 ~ 200) s-1, futhi lingalandelela ijika elinobukhulu obubili lezinga lokugunda kanye ne-viscosity ngesikhathi sangempela. Isimiso sokulinganisa sidwetshwe ku-Newton Viscidity Theorem.

Ukucaciswa Kobuchwepheshe

Imodeli I-SA6600
Isimiso Igazi eliphelele: Indlela yokujikeleza;
I-Plasma: Indlela yokujikeleza, indlela ye-capillary
Indlela Indlela yepuleti lekhoni,
indlela ye-capillary
Iqoqo lesiginali Indlela yepuleti lekhoni: Ubuchwepheshe bokuhlukanisa i-raster obunembile kakhulu Indlela ye-capillary: Ubuchwepheshe bokubamba obuhlukile obunomsebenzi wokulandelela okuzenzakalelayo koketshezi
Imodi Yokusebenza Ama-probe amabili, amapuleti amabili kanye nezindlela ezimbili zisebenza ngasikhathi sinye
Umsebenzi /
Ukunemba ≤±1%
CV I-CV≤1%
Isikhathi sokuhlola Igazi eliphelele ≤30 sec/T,
i-plasma≤0.5sec/T
Izinga lokucheba (1~200)s-1
Ukuthamba (0~60)mPa.s
Ukucindezeleka okuncishisiwe (0-12000)mPa
Ivolumu yokusampula Igazi eliphelele: 200-800ul elungisekayo, i-plasma≤200ul
Indlela yokusebenza I-alloy ye-titanium, i-jewel bearing
Isikhundla sesampula Isikhundla sesampula esingu-60 esine-rack eyodwa
Isiteshi sokuhlola 2
Uhlelo loketshezi Iphampu ye-peristaltic ecindezela kabili, i-Probe enenzwa yoketshezi kanye nomsebenzi wokuhlukanisa i-plasma ngokuzenzakalelayo
Isixhumi esibonakalayo I-RS-232/485/USB
Izinga lokushisa 37℃±0.1℃
Ukulawula Ishadi lokulawula le-LJ elinomsebenzi wokulondoloza, umbuzo, wokuphrinta;
Ukulawulwa koketshezi okungeyona i-Newtonian kokuqala okunesitifiketi se-SFDA.
Ukulinganisa uketshezi lwe-Newtonian olulinganiswa uketshezi lwe-viscosity oluyinhloko lukazwelonke;
Isitifiketi sokuwina uphawu olujwayelekile lukazwelonke olungeyona i-Newtonian fluid yi-AQSIQ yaseShayina.
Umbiko Vula

1. Indawo yokusebenza:

1.1 I-Voltage (220±22)V;
1.2 Imvamisa (50±1) Hz;
1.3 Amandla okufaka angu-400VA
1.4 Indawo yokusebenza: izinga lokushisa 10℃~30℃

Umswakama ohlobene 45%~85%

Ingcindezi yomoya 86.0kPa~106.0kPa
1.5 Akukho ukuphazamiseka okukhulu kwensimu kagesi, ukudlidliza okunamandla, kanye negesi egqwalisayo eduze kwesistimu yokuhlola.
1.6 Uhlelo lokuhlola kufanele lugcinwe kude nokukhanya kwelanga okuqondile futhi kude nemithombo yokushisa.
1.7 Ngaphandle kwezinsimbi ezikhethekile ezikhiqizwe ngokwezidingo ezikhethekile, zikhawulelwe ukusetshenziswa ngaphakathi.

2. Isigaba sokuphepha:

2.1 Umthombo wamandla wenethiwekhi kumele ube ne-ground terminal evikelayo. I-ground terminal evikelayo yangaphakathi yethuluzi imakwe ngophawu futhi kumele isekelwe ngokuthembekile nge-socket kagesi. Isivikelo sokuvuza kufanele sifakwe uma sisetshenziswa endaweni emanzi.

2.2 Ipuleti legama lethuluzi liphawulwe ngegama lethuluzi, imodeli, igama lenkampani, inombolo yefektri, i-voltage yokunikezwa kwamandla elinganisiwe, imvamisa yokunikezwa kwamandla, amandla okufaka kanye nezinye izimpawu.

2.3 Ingaphandle lethuluzi liphawulwe ngophawu lwesixwayiso, okusho ukuthi umsebenzi wenziwa ngumsebenzisi. Incazelo eningiliziwe yomsebenzi inikezwe kule ncwadi, sicela uyibhekisele kuyo.

2.4 Izinsimbi ezikhiqizwe yinkampani yethu zinezindlela zokuzivikela ekupakisheni kwezokuthutha. Ngemva kokuba ithuluzi selifakiwe futhi lisebenza, ngokuvamile akufanele lisuswe, ngakho-ke sicela ulinake ngokukhethekile.
2.5 Ngaphandle kokuthi kunezindlela zokulungisa kule ncwadi, sicela ungayivuli ukuze uyilungise wedwa, kuzokwenza ubhekane ne-voltage ephezulu noma ezinye izingozi. Ukulungiswa kwalezi zingxenye kufanele kunikezwe ochwepheshe.
2.6 Isiphelo sokusekela sensimbi yamandla kumele sisekelwe ngokuthembekile ngesokhethi yamandla. Kufanele kufakwe isivikelo sokuvuza uma sisetshenziswa endaweni emanzi.
2.7 Njengoba ifakwe isilawuli samandla ethuluzini, ngokuvamile asikho isidingo sesilawuli sangaphandle. Lapho i-voltage yokunikezwa kwamandla yangaphandle ishintshashintsha ngaphezu kuka-220V ± 22V, iziqinisi zama-voltage zohlobo lwe-UPS zingasetshenziswa esikhundleni seziqinisi zama-voltage ezivamile.

  • mayelana nathi01
  • mayelana nathi02
Bhala umlayezo wakho lapha bese uwuthumela kithi

IMIKHIQIZO IZIGABA

  • I-Semi Automated Blood Rheology Analyzer
  • I-Analyzer ye-Blood Rheology Ezenzakalelayo Ngokugcwele
  • I-Analyzer ye-Blood Rheology Ezenzakalelayo Ngokugcwele
  • I-Analyzer ye-Blood Rheology Ezenzakalelayo Ngokugcwele
  • I-Analyzer ye-Blood Rheology Ezenzakalelayo Ngokugcwele
  • Amakhithi Okulawula E-Blood Rheology